Clock, Logging & Persistence (S13-S15)

§13 — Real-time clock & time synchronisation

As a software E-SDC there is no dedicated hardware RTC. Time accuracy is maintained by NTP synchronisation against the server provided by FRCS (set via SetTimeServerUrl), performed hourly — well within the 48-hour requirement. Between syncs the host system clock is the time source. This is the documented alternative to a hardware RTC for an application-based E-SDC.

§14 — Logging

XPOS ESDC records the required error events: invoice, APDU, TaxCore, internal, initialization, fiscalization, audit and time-synchronisation errors. Log characteristics:

§15 — Persistence & offline capacity

Invoice records and encrypted audit packages are stored in a local embedded database that survives power loss and restart (non-volatile). No power is required to preserve fiscal data.

Offline capacity: an audit package is approximately 3–5 KB, giving at least ~100,000 unsent invoices per GB of free storage. The device therefore sustains extended offline operation, reporting automatically once connectivity returns.


Revision #1
Created 2026-08-13 08:42:43 UTC by Shanil Verma
Updated 2026-08-13 08:42:43 UTC by Shanil Verma